• Inventory
  • Products
  • Technical Information
  • Circuit Diagram
  • Data Sheet
Data Sheet
Home > Data Sheet > 6N135
6N135

6N135

Model 6N135
Description General Purpose Type Photocoupler
PDF file Total 5 pages (File size: 74K)
Chip Manufacturer SHARP
6N135/6N136
6N135/6N136
s
Features
1. High speed response t
PHL
, t
PLH
(
6N135
: MAX. 1.5
µ
s at R
L
= 4.1k
)
(
6N136
: MAX. 0.8
µ
s at R
L
= 1.9k
)
2. High common mode rejection voltage
( CM
H
: TYP. 1kV/
µ
s )
3. Standard dual-in-line package
4. Recognized by UL, file No. E64380
General Purpose Type
Photocoupler
s
Outline Dimensions
0.85
±
0.3
8
7
6N
6
Model
1.2
±
0.3
No.
5
6.5
±
0.5
( Unit : mm )
Internal
connection
diagram
8
7
6
5
1
2
3
4
0.8
1
2
3
4
s
Applications
1. Computers, measuring instruments, control
equipment
2. High speed line receivers, high speed logic
3. Telephone sets
4. Signal transmission between circuits of
different potentials and impedances
0.5TYP
3.5
±
0.5
Primary side mark
(Sunken place )
9.22
±
0.5
7.62
±
0.3
3.7
±
0.5
θ
=
0 to 13˚
0.5
±
0.1
2.54
±
0.25
0.26
±
0.1
GND
V
O
V
B
θ
1
2
3
NC
Anode
Cathode
NC
5
6
7
8
s
Absolute Maximum Ratings
Parameter
Forward current
*1
Peak forward current
Input
*2Peak
transient
forward current
( Ta = 25˚C )
Rating
25
50
1
5
45
- 0.5 to + 15
- 0.5 to + 15
5
8
16
5
100
2 500
- 55 to + 100
- 55 to + 125
260
Unit
mA
mA
A
V
mW
V
V
V
mA
mA
mA
mW
V
rms
˚C
˚C
˚C
4
V
CC
Reverse voltage
Power dissipation
Supply voltage
Output voltage
Emitter-base reverse with-
( Pin 5 to 7
stand voltage
)
Output
Average output current
Peak output current
Base current ( Pin 7 )
Power dissipation
*3
Isolation voltage
Operating temperature
Storage temperature
*4
Soldering temperature
Symbol
I
F
I
F
I
FM
V
R
P
V
CC
V
O
V
EBO
I
O
I
OP
I
B
P
O
V
iso
T
opr
T
stg
T
so1
* “ OPIC ” ( Optical IC ) is a trademark of the SHARP Corporation.
An OPIC consists of a light-detecting element and signal-
processing circuit integrated onto a single chip.
*1 50% duty cycle, Pulse width : 1ms
Decreases at the rate of 1.6mA/˚C if the external temperature is 70˚C or more.
*2 Pulse width<=1µ s, 300
P
/
S
*3 40 to 60% RH, AC for 1 minute
*4 For 10 seconds
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.”
Go Upload

* Only PDF files are allowed for upload

* Enter up to 200 characters.