• Inventory
  • Products
  • Technical Information
  • Circuit Diagram
  • Data Sheet
Data Sheet
Home > Data Sheet > B1101UA
B1101UA

B1101UA

Model B1101UA
Description SIDACtor devices
PDF file Total 212 pages (File size: 2M)
Chip Manufacturer TECCOR
Analog Line Cards
Off-Hook (SLIC) Protection
Off-hook protection is accomplished by choosing a
SIDACtor
device that meets the
following criteria to ensure proper coordination between the supply voltage (V
REF
) and the
maximum voltage rating of the SLIC to be protected.
V
DRM
> V
REF
V
S
£
V
SLIC Breakdown
This criterion can be accomplished in a variety of different ways. For applications using an
external ring generator and a fixed battery voltage, two P0641S_
SIDACtor
devices
(P0721S_, P0901S_, or P1101S_ depending on the value of V
REF
) are used — one Tip to
Ground, one Ring to Ground. For applications using a ring-generating SLIC such as AMD’s
Am79R79, the B1XX0C_ or B1XX1U_ can be used.
I
PP
Selection
The I
PP
of the
SIDACtor
device must be greater than or equal to the maximum available
surge current (I
PK(available)
) of the applicable regulatory requirements. Calculate the maximum
available surge current by dividing the peak surge voltage supplied by the voltage generator
(V
PK
) by the total circuit resistance (R
TOTAL
). The total circuit resistance is determined by
adding the source resistance (R
S
) of the surge generator to the series resistance in front of
the
SIDACtor
device on Tip and Ring (R
TIP
and R
RING
).
I
PP
³
I
PK(available)
I
PK(available)
= V
PK
/ R
TOTAL
For metallic surges:
R
TOTAL
= R
S
+ R
TIP
+ R
RING
For longitudinal surges:
R
TOTAL
= R
S
+ R
TIP
R
TOTAL
= R
S
+ R
RING
Reference Diagrams
Figure 3.21 shows the use of Teccor’s “SC” rated
SIDACtor
devices and the F1250T
TeleLink
fuse to meet the surge immunity requirements of GR 1089. Teccor’s P1200SC and
P2000SC, specifically designed to protect Agere Systems (formerly Lucent
Microelectronics) Line Card Access Switch (LCAS), provide on-hook protection. Two
P0641SCs provide off-hook protection. Any additional series resistance is absent because
the “C” series
SIDACtor
device and F1250T
TeleLink
fuse are designed to withstand
GR 1089 surges without the aid of additional components such as line feed resistors and
PTCs.
http://www.teccor.com
+1 972-580-7777
3 - 18
SIDACtor
®
© 2002 Teccor Electronics
Data Book and Design Guide
Go Upload

* Only PDF files are allowed for upload

* Enter up to 200 characters.