Data Sheet
Home > Data Sheet > C01610D00380612
C01610D00380612

C01610D00380612

Model C01610D00380612
Description Circular Connector
PDF file Total 20 pages (File size: 2M)
Chip Manufacturer AMPHENOL
Technical Information
Degree of Protection
Electrical devices to which connectors belong to have to be protected for
safety reasons from outside influences like dust, foreign objects, direct
contact, moisture and water. This protection is provided on industrial
connectors by its housings with their latching devices and sealed cable
entries. The degree of protection can be selected depending on the type of
intended use. The standard IEC 60529 and/or DIN EN 60529/VDE 0470
Part 1 has specified the degree of protection and divided into several classes.
The degree of protection is indicated in the following way:
IP65
Code letters
(Internat. Protection)
1st charact. numeral (degree of protection against access
to hazardous parts and against solid foreign objects)
2nd charact. numeral (degree of protection against ingress of water)
The following charts 4 an 5 give an overview about all protection degrees.
2
Protected against vertically Vertically falling drops shall
falling water drops when have no harmful effects when
enclosure tilted up to 15° the enclosure is tilted at any
angel up to 15° on either side
of the vertical.
Protected against spraying Water sprayed at an angle up
water
to 60° on either side of the
vertical shall have no harmful
effects.
Protected against splashing Water splashed against the
enclosure from any direction
water
shall have no harmful effects.
Protected against water jets Water projected in jets against
the enclosure from any
direction shall have no harmful
effects.
Protected against powerful Water projected in powerful
jets against the enclosure
water jets
from any direction shall have
no harmful effects.
Protected against the effects Intrusion of water in quantities
of temporary immersion in causing harmful effects
shall not be possible when
water
the enclosure is temporalily
immersed in water for 30 min.
in 1m depth.
Protected against the effects Intrusion of water in quantities
of continous immersion in causing harmful effects shall
water
not be possible when the
enclosure is continuously
immersed in water under
conditions which shall be
agreed between manufacturer
and user but which are more
severe than for numeral 7.
Chart 5
2nd charact. Brief description
numeral
0
1
Non-protected
Definition
Protected against vertically Vertically falling drops shall
have no harmful effects.
falling water drops
3
Chart 4
1st charact. Brief description
numeral
0
1
Non-protected
Protected against access to
hazardous parts with the back
of a hand. Protected against
solid foreign objects of
≥ 50mm Ø.
Protected against access to
hazardous parts with a finger.
Protected against solid
foreign objects of
≥ 12,5mm Ø.
Definition
4
The probe, sphere of 50mm
Ø, shall not fully penetrate and
shall have adequate clearance
from hazardous parts.
The jointed test finger of
12mm Ø, 80mm length,
shall have adequate clearance
from hazardous parts. The
probe, sphere of 12,5mm Ø,
shall not fully penetrate.
5
2
6
7
3
Protected against access The probe of 2,5mm Ø shall
to hazardous parts with a not penetrate at all.
tool. Protected against solid
foreign objects of
≥ 2,5mm Ø.
Protected against access to The probe of 1mm Ø shall
hazardous parts with a wire. not penetrate at all.
Protected against solid
foreign objects of ≥ 1mm Ø.
Protected against access to The probe of 1mm Ø shall
hazardous parts with a wire. not penetrate.
Intrusion of dust is not
Dust-protected.
totally prevented, but dust shall
not penetrate in a quantity
to interfere with satisfactory
operation of the device or to
impair safety.
Protected against access to The probe of 1mm Ø shall
hazardous parts with a wire not penetrate.
Dust-tight.
No intrussion of dust.
1)
4
8
5
9K
1)
6
Protected against water
Water projected in powerful
during high pressure/steam jets with high pressure against
jet cleaning
the enclosure from any
direction shall have no harmful
effects.
Remark: Numeral acc. to DIN 40050 part 9, vehicles IP code.