• Inventory
  • Products
  • Technical Information
  • Circuit Diagram
  • Data Sheet
Data Sheet
Home > Data Sheet > F.MG.01A.01.03.FA
F.MG.01A.01.03.FA

F.MG.01A.01.03.FA

Model F.MG.01A.01.03.FA
Description Mains Power Connector, 1A, 250VAC, Male, Solder Terminal
PDF file Total 3 pages (File size: 718K)
Chip Manufacturer KEMET
IEC Inlet Filters
With fuse holders and voltage selectors
A range of compact IEC 60320 inlet power entry modules combining
1 or 2 fuse holders for US and IEC fuses. Plus input voltage selector
with 4 possible combinations. These features ensure the range is
ideally suited for manufacturers of business, consumer and medical
equipment for international markets.
F.MF-F.MG
series
Current ratings from 1A to 6A
Integral single or twin fuse holder
Voltage selector
Snap-in or screw mount versions
Medical versions available
Mechanical Specifications
Manufacture:
metal case with built-in power line connector
according to IEC 60320, 1 (F.MF) or 2 (F.MG) fuse
holders for fuses 5 x 20mm (IEC) or 6.3 x 32mm
(US), voltage selector with 4 possible combinations;
internal components sealed with self-extinguishing
resin.
Connections:
IEC 60320 - Standard plug (INPUT);
faston 6.3 x 0.5mm or 2.8 x 0.5mm for filter
output terminals;
faston 2.8 x 0.5mm for fuse terminals;
faston 2.8 x 0.5mm for voltage selector terminals;
ground terminal connected to case.
F.MF.
01.– –.– –
01A. 04.– –.– –
07.– –.– –
02.– –.– –
3
2 x 2.5 0.047
2 x 2500
6
2x1
0.047
08.– –.– –
03.– –.– –
06A. 06.– –.– –
09.– –.– –
2 x 2500
F.MG. 03A. 05.– –.– –
1
2 x 10
0.047
Filter Range
(example pt no. - F.MF.01A.01.01.FA)
Code
l
R
(A)
L
(mH)
Cx
(µF)
Cy
(pF)
2 x 2500
I
L
(mA)
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
1
1
1
R
(MΩ)
Electrical Specifications
Rated voltage (V
R
):
max 250V, 50/60Hz
Rated current (I
R
):
Voltage test (2
S
.):
Climatic category:
Voltage selector:
referred to room temperature = 40°C
line to ground 3000Vdc or 1800Vac
line to line 1700Vdc
HPF (25/085/21);
Temperature range: -25°C to +85°C
110-220-240Vac
100-120-220-240Vac
115-115-230-230Vac
110-220Vac
Leakage current (I
L
):
at 220V, 50Hz, max value
F = 1 fuse
G = 2 fuses
A = Filter output terminals 2.8 x 0.5mm
C = Filter output terminals 6.3 x 0.8mm
F = Snap-in mounting
G = Screw mounting
01 = fuse 5 x 20mm + voltage selector 110-220-240V~
02 = fuse 5 x 20mm + voltage selector 100-120-220-240V~
03 = fuse 5 x 20mm + voltage selector 115-115-230-230V~
08 = fuse 6.3 x 32mm + voltage selector 110-220-240V~
09 = fuse 6.3 x 32mm + voltage selector 100-120-220-240V~
10 = fuse 6.3 x 32mm + voltage selector 115-115-230-230V~
15 = fuse 5 x 20mm + voltage selector 110-220V~
16 = fuse 6.3 x 32mm + voltage selector 110-220V~
19 = fuse 5 x 20mm + voltage selector 100-120-220-230V~
20 = fuse 6.3 x 32mm + voltage selector 100-120-230-240V~
21 = fuse 5 x 20mm + voltage selector 100-120-230-240V~