• Inventory
  • Products
  • Technical Information
  • Circuit Diagram
  • Data Sheet
Data Sheet
Home > Data Sheet > F.MM.06A.37.26
F.MM.06A.37.26

F.MM.06A.37.26

Model F.MM.06A.37.26
Description Mains Power Connector, 6A, 250VAC, Male, Solder Terminal
PDF file Total 2 pages (File size: 696K)
Chip Manufacturer KEMET
IEC Inlet Filters
F.MH-F.MK-F.ML-F.MM-F.MP-F.MQ-F.MR-F.MS
series
With fuse holder, bipolar switch and voltage selector
This series gives a high level of suppression within a compact
enclosure. The IEC 60320 inlet power entry module combines 1 or 2
fuse holders for US and IEC fuses, with a bipolar rocker switch, earth
choke and input voltage selector.
Designed for use in business, consumer, test and medical equipment
for international markets.
Current ratings from 1A to 6A
Comprehensive range of filter performance options
Integral single or twin fuse holder
Optional voltage selector
Optional earth line choke
Horizontal or vertical mounting
Medical versions available
Mechanical Specifications
Manufacture:
metal case with built-in power line connector
according to IEC 60320,
fuse holder for 1 fuse (F.MH. - F.ML. - F.MP. - F.MR)
or 2 fuses (F.MK. - F.MM. - F.MQ. - F.MS)
5 x 20mm (IEC) or 6.3 x 32mm (US),
bipolar rocker switch,
voltage selector 110/220Vac (F.MH - F.MK - F.ML
- F.MM only); internal components sealed with
self-extinguishing resin.
Connections:
IEC 60320 - Standard plug (INPUT);
faston 6.3 x 0.8mm (OUTPUT);
ground terminal connected to case.
Mounting:
F.MH, F.MK, FML, FMM versions now available in
vertical mounting version - (F.**.***.**.**.010) with
no approvals.
Filter Range
(example pt no. - F.MH.01A.20.25)
Code
20.- -
01A 24.- -
30.- -
34.- -
21.- -
2A5 25.- -
31.- -
35.- -
22.- -
04A 26.- -
32.- -
36.- -
23.- -
06A 27.- -
33.- -
37.- -
20.- -
01A 24.- -
30.- -
34.- -
21.- -
2A5 25.- -
31.- -
35.- -
22.- -
04A 26.- -
32.- -
36.- -
23.- -
06A 27.- -
33.- -
37.- -
I
R
L
1
(A) (mH)
2 x 10
1
2 x 10
2 x 22
2 x 22
2x2
2.5 2 x 2
2x8
2x8
2x1
4
2x1
2x8
2x8
2x1
6
2x1
2 x 2.5
2 x 2.5
2 x 10
1
2 x 10
2 x 22
2 x 22
2x2
2.5 2 x 2
2x8
2x8
2x1
4
2x1
2x8
2x8
2x1
6
2x1
2 x 2.5
2 x 2.5
L
2
Cx
1
(mH) (µF)
0.22
Cx
2
(µF)
0.1
Cy
(pF)
2 x 4700
2 x 4700
2 x 4700
F.MH.
F.MK.
F.MQ.
F.MS.
0.22
0.1
2 x 4700
2 x 4700
0.22
0.1
2 x 4700
2 x 4700
0.22
0.1
2 x 4700
2 x 4700
0.1
2 x 4700
0.65 0.22
2 x 4700
0.1
2 x 4700
Electrical Specifications
Rated voltage (V
R
):
max 250V, 50/60Hz
Rated current (I
R
):
Voltage test (2
S
.):
Climatic category:
Bipolar rocker
Switches:
referred to room temperature = 40°C
line to ground 3000Vdc or 1800Vac
line to line 1700Vdc
HPF (25/085/21);
Temperature range: -25°C to +85°C
10(4)A / 250Vac (Rated current),
50000 on-off operations;
values in ( ) relate to the inductive current;
inrush current test according to UL 1054 (35A).
Voltage selector:
110-220Vac (F.MH - F.MK - F.ML - F.MM only).
Leakage current (I
L
):
at 220V, 50Hz, max value
F.ML.
F.MM.
F.MP.
F.MR.
0.65 0.22
2 x 4700
0.1
2 x 4700
0.65 0.22
2 x 4700
0.1
2 x 4700
2 x 0.003
0.65 0.22
l
L
(mA)
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
R
(M
Ω
)
0.33
0.33
0.33
0.33
0.33
0.33
0.33
0.33
No approvals, Circuit Diagram D
No approvals, Circuit Diagram C
Not applicable to FMP,FMR
Approvals
32
.010 = Vertical mounting option (addition to standard pt no.)
25 = Rocker switch
26 = Illuminated rocker switch
Circuit Diagram:
H = 1 fuse
A
K = 2 fuses
L = 1 fuse + earth choke
B
M = 2 fuses + earth choke
P = 1 fuse, single pole switch (no voltage selector)
D
Q = 2 fuses, single pole switch (no voltage selector)
R = 1 fuse, double pole switch (no voltage selector)
C
S = 2 fuses, double pole switch (no voltage selector)
Go Upload

* Only PDF files are allowed for upload

* Enter up to 200 characters.