• Inventory
  • Products
  • Technical Information
  • Circuit Diagram
  • Data Sheet
Data Sheet
Home > Data Sheet > H/MSA3106A18-10SX-G
H/MSA3106A18-10SX-G

H/MSA3106A18-10SX-G

Model H/MSA3106A18-10SX-G
Description MS type Lower Profile Plug(Circular connector conforming to MIL-C-5015)
PDF file Total 29 pages (File size: 1M)
Chip Manufacturer HRS
B
Assembly Procedures
Process
Outline of assembly
B
B
A
Pre-solder
Conductor portion
A
Contacts
Back-shell
B
Solder
Bushing
1
Insulator/contact assembly
Washer
A
18-10 Size
22-22 Size
24mm
33mm
B
13mm
15mm
Strain relief clamp
a. Pass the strain relief clamp, washer, bushing, and hood over the cable, in this order.
b. Prepare the cable and conductors per the dimensions in Table 1.
c. Bend the exposed conductor to the B dimension as indicated in Table 1.
d. Pre-solder the exposed conductor and solder it as shown to the exposed contact.
Note: Use care not to damage the conductor’s insulation.
4.5 mm min.
Back-shell
Set screw
(Hexagonal hole opposite side 1.27 mm)
3057-10
Locking ring
2
Table 2
Locking Ring
3 to 3.5N • m
Cable Clamp
5 to 6N • m
a. Place over the contact/insulator assembly (in the following order:Back shell, bushing, washer, strain relief clamp).
b. Tighten the Locking ring and Cable clamp to the torque values per Table 2.
c. Tighten the set screw to a torque value of 0.3-0.4 N-m
HRS recommended tool: PB205/1.27 (CL150-0066-3)or equivalent.
d. Using screwdriver tighten the two strain relief clamp screws until both sides of the moveable part are in contact with the cable clamp.
®
5-23,OSAKI 5-CHOME,SHINAGAWA-KU,TOKYO 141-8587,JAPAN
PHONE: 81-3-3491-9741, FAX: 81-3-3493-2933
http://www.hirose.com
4
The contents of this catalog are current as of date of publication. Contents are subject to change without notice for the purpose of improvements.
30
57
Table 1
-10
Cable
Strain relief clamp
Screw
Cable
Clamp
Washer
Bushing
Go Upload

* Only PDF files are allowed for upload

* Enter up to 200 characters.