S101S05V

Model S101S05V
Description SIP Type SSR with Mounting Capability for External Heat Sink
PDF file Total 4 pages (File size: 64K)
Chip Manufacturer SHARP
S101S05V/S101S06V/S201S05V/S201S06V
S101S05V/S101S06V
S201S05V/S201S06V
s
Features
1. High radiation resin mold package.
2. RMS ON-state current
I
T
: MAX. 3Arms at T <= 100˚C
C
( With heat sink)
3. Isolation voltage between input and output
(V
iso
: 3 000 V
rms
)
4. Built-in zero-cross circuit
( S101S06V/S201S06V )
5. Recognized by UL, file No. E94758
Approved by CSA, No. LR63705
SIP Type SSR with
Mounting Capability for
External Heat Sink
s
Outline Dimensions
( Unit : mm )
* The metal parts marked *
are common to terminal 1 .
g
Do not allow external connection.
( )
:
Typical dimensions
18.5
±
0.2
16.4
±
0.3
φ
3.2
±
0.2
A ( Model No. )
B
S101S05V
3A125VAC
S101S06V
S201S05V
3A265VAC
S201S06V
3.2
±
0.2
5.5
±
0.2
19.6
±
0.2
5.0
±
0.3
(36.0)
*
g
0.2
MAX.
A
B
+ -
4.2
MAX.
1. OA equipment such as copiers
2. FA equipment
1
2
3
4
11.2
MIN.
0.6
±
0.1
s
Applications
4
4
4
-
1.1
±
0.2
-
1.25
±
0.3
-
0.8
±
0.2
s
Model Line-ups
For 100V lines
No built-in
zero-cross circuit
Built-in
zero-cross circuit
S101S05V
S101S06V
For 200V lines
S201S05V
S201S06V
(5.08) (7.62)
Internal connection diagram
S101S05V
/S201S05V
(2.54)
(1.4)
S101S06V
/S201S06V
Zero-cross
circuit
1
1
2
3
4
2
3 4
Output ( Triac T2 )
Output ( Triac T1 )
Input (
+
)
Input (
-
)
1 2
1
2
3
4
3 4
Output ( Triac T2 )
Output ( Triac T1 )
Input (
+
)
Input (
-
)
s
Absolute Maximum Ratings
Parameter
Input
Forward current
Reverse voltage
RMS ON-state current
*1
Peak one cycle surge current
Repetitive peak OFF-state voltage
Non-repetitive peak OFF-state voltage
Critical rate of rise of ON-state current
Operating freguency
*2
Isolation voltage
Operating temperature
Storage temperature
*3
Soldering temperature
Symbol
I
F
V
R
I
T
I
surge
V
DRM
V
DSM
dI
T
/dt
f
V
iso
T
opr
T
stg
T
sol
( Ta = 25˚C )
Rating
S101S05V / S101S06V S201S05V / S201S06V
50
6
*4
3
30
400
600
400
600
40
45 to 65
3 000
- 25 to + 100
- 30 to + 125
260
Unit
mA
V
A
rms
A
V
V
A/
µ
s
Hz
V
rms
˚C
˚C
˚C
Output
*1 60Hz sine wave, start at Tj= 25˚C
*2 60Hz AC for 1 minute, 40 to 60% RH. Apply voltages between input and output, by the dielectric withstand
voltage tester with zero-cross circuit. ( Input and output shall be shorted respectively)
( Note) When the isolation voltage is necessary at using external heat sink, please use the insulation sheet.
*3 For 10 seconds
*4 Tc<=100˚C
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.”
Go Upload

* Only PDF files are allowed for upload

* Enter up to 200 characters.