• Inventory
  • Products
  • Technical Information
  • Circuit Diagram
  • Data Sheet
Data Sheet
Home > Data Sheet > U.FL-2LP-088N2T-A-(L)
U.FL-2LP-088N2T-A-(L)

U.FL-2LP-088N2T-A-(L)

Model U.FL-2LP-088N2T-A-(L)
Description CABLE TERMINATED, MALE, RF CONNECTOR, PLUG, ROHS COMPLIANT
PDF file Total 7 pages (File size: 193K)
Chip Manufacturer HRS
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the
Surface Mount
search at www.hirose-connectors.com, or contact your Hirose sales
Height
U.FL SeriesqUltra Small
Hirose website RoHS
Coaxial Connectors - 1.9mm or 2.4mm Mated
representative.
sUsage
Precautions
1. Plugs
1) To disconnect connectors, insert the end portion of U.FL-LP-N-2 and U.FL-LP(V)-N-2 under the connector flanges
and pull off vertically, in the direction of the connector mating axis.
2) To mate the connectors, the mating axes of both connectors must be
Extraction Jig
aligned and the connectors can be mated. The "click" will confirm fully
U.FL Cable
mated connection.Do not attempt to insert on an extreme angle.
Assembly
(1) Mating / unmating
U.FL-R-SMT-1
After the connectors are mating, do not apply a load to the cable in excess of the values indicated in the diagram
below.
U.FL-LP
Cable Assembly
1N max (U.FL-LP(V)-040, U.FL-LP-062)
2N max (U.FL-LP-040, U.FL-LP-066, U.FL-LP-088)
(2) Pull forces on the
cable after connectors
are mated.
U.FL-R-SMT-1
3N max (U.FL-LP(V)-040, U.FL-LP-062)
4N max (U.FL-LP-040, U.FL-LP-066, U.FL-LP-088)
1N max (U.FL-LP(V)-040, U.FL-LP-062)
2N max (U.FL-LP-040, U.FL-LP-066, U.FL-LP-088)
(3) Precautions
Do NOT forcefully twist or deform wires.
2. Receptacles
[ç]
260
240
220
200
180
160
140
120
100
80
250 ç max. for
10 seconds
230ç
220ç
(1) Recommended reflow
temperature profile
Preheat
(130 to 180ç)
120 seconds max.
50 seconds max.
60 seconds max.
q
The temperature of the printed circuit board
surface temperature at the points of contact with
the terminals.
w
Reflow soldering should be performed at a
printed circuit surface temperature of 250°C max.
e
In individual applications the actual temperature
may vary, depending on the solder paste type,
volume / thickness and board size / thickness.
Consuly your solder paste and equipment
manufacturer for specific recommendations.
Time
(2) Recommended
manual soldering
(3) Recommended metal
mask thickness
(4) Reflow cycles
Manual soldering: 350˚C for 5 seconds
0.1 to 0.12 mm
2 times
3. Operating environment and storage conditions
(1) Operating environment
The connectors are not designed to operate in the following environments:
Exposed to a excessive amounts of fine particles and dust
Regions and places having a high density of sulfur dioxide, hydrogen sulfide, nitrogen dioxide or other corrosive gasses.
Environments having large rapid variations in temperature.
Store in the Hirose Electric packaging.
Temperature: -10 to +40ç, Humidity: 85% max.
Use within 6 months of delivery.
Receptacles for which the storage period has elapsed must be tested for solderability to the PC board mounting surface.
(2) Storage conditions -
Receptacle