• Inventory
  • Products
  • Technical Information
  • Circuit Diagram
  • Data Sheet
Data Sheet
Home > Data Sheet > B3164U
B3164U

B3164U

Model B3164U
Description solid state crowbar devices
PDF file Total 212 pages (File size: 2M)
Chip Manufacturer TECCOR
GR 1089–Core
First Level AC Power Fault Criteria
Table 4.6 presents test conditions for the First Level AC Power Fault Test. The EUT is
required to pass operationally.
Table 4.6
First Level AC Power Fault Test
Applied Voltage,
60 Hz
(V
RMS
)
50
100
200, 400, 600
1000
N/A
600
600
600
1000
Short Circuit
Current per
Conductor
(A)
0.33
0.17
1A at 600 V
1
N/A
0.5
2.2
3
5
Test
1 (Note 1)
2 (Note 1)
3 (Note 1)
4 (Note 4)
5 (Note 2)
6 (Note 3)
7 (Note 3)
8 (Note 3)
9 (Note 3)
Duration
15 min
15 min
60 applications,
1 s each
60 applications,
1 s each
60 applications,
5 s each
30 s
2s
1s
0.5 s
Primary
Protectors
Removed
Removed
Removed
In place
Removed
Removed
Removed
Removed
In place
Test Connections
(Table 4.1, Figure 4.1)
A
A
A
B
N/A
A
A
A
B
Second Level AC Power Fault Criteria
Test conditions for the Second Level AC Power Fault Test are dependent on whether the
EUT is intended for customer premises equipment or non-customer premises equipment. In
both instances, although the EUT is not required to pass operationally, it may not become a
fire, fragmentation, or electrical safety hazard.
Second Level AC Power Fault Criteria for Non-customer Premises
Equipment
Table 4.7 presents test conditions for non-customer premises equipment. (Note that test
conditions 1, 3, and 4 may be omitted if the EUT has previously met UL 60950.) See
Figure 4.1 for test connection appearances.
© 2002 Teccor Electronics
SIDACtor
®
Data Book and Design Guide
4-7
http://www.teccor.com
+1 972-580-7777
Regulatory
Requirements
Notes:
1. For EUT containing secondary voltage limiting and current limiting protectors, tests are to be performed at the indicated voltage(s)
and repeated at a reduced voltage and current just below the operating threshold of the secondary protectors.
2. Test 5 simulates a high impedance induction fault. For specific information, please contact Teccor Electronics.
3. Test conditions 6 through 9 are objective, not mandatory, requirements.