AC Power Fault Test is that the EUT may be damaged, but it may not become a fire,
fragmentation, or electrical safety hazard. Passing criteria for the Current Limiter Test is that
the EUT may be damaged but it may not exceed the acceptable time/current criteria (that is,
cannot cause the wiring simulator as shown in Figure 4.2 to open) nor become a fire,
fragmentation, or electrical safety hazard.
The indicator used in measuring fire, fragmentation, and electrical safety hazards is a
bleached, untreated cotton cheesecloth wrapped around the EUT. Compliance with testing
is determined by the absence of ignition, charring, and the ejection of molten material or
fragments.
First Level Lightning Surge Test
To pass the First Level Lightning Surge Test, the EUT must be undamaged and continue to
operate properly after the stress is applied. This is referred to as passing “operationally.”
Table 4.3 presents the conditions for the First Level inter-building criteria. Applicants have
the option to submit their equipment to meet surges 1, 2, 4, and 5 or surges 3, 4, and 5.
Table 4.4 presents the conditions for the intra-building criteria.
Table 4.3
First Level Lightning Surge Test
Surge Voltage
(V
PK
)
±600
±1000
±1000
±2500
±1000
Waveform
(µs)
10x1000
10x360
10x1000
2x10
10x360
Surge Current
per Conductor
(A)
100
100
100
500
25
Repetitions
Each Polarity
25
25
25
10
5
Test
Connections
(Table 4.1, Figure 4.1)
A
A
A
B
B
Test
(Notes 1 & 2)
1
2 (Note 3)
3 (Note 3)
4 (Note 4)
5 (Note 5)
Notes:
1. Primary protectors are removed for all tests.
2. For EUT containing secondary voltage limiting and current limiting protectors, tests are to be performed at the indicated voltage(s)
and repeated at a reduced voltage and current just below the operating threshold of the secondary protectors.
3. Test 1 and 2 can be replaced with Test 3 or vice versa.
4. Alternatively, a surge generator of 1.2x50 µs open-circuit voltage waveform (8x20 µs short-circuit current waveform) per
IEEE C62.41 may be used. The current shall be limited by the inclusion of a series 3
W
resistor placed externally to the surge
generator.
5. This test is to be performed on up to 12 Tip and Ring pairs simultaneously.
Table 4.4
Intra-Building Lightning Surge Test
Surge Voltage
(V
PK
)
±800
±1500
Wave-form
(µs)
2x10
2x10
Surge Current
per Conductor
(A)
100
100
Repetitions Each
Polarity
1
1
Test Connections
(Table 4.1, Figure 4.1)
A1, A2
B
Test
1
2
Notes:
• For EUT containing secondary voltage limiting and current limiting protectors, tests are to be performed at the indicated voltage(s)
and repeated at a reduced voltage and current just below the operating threshold of the secondary protectors.
• Alternatively, a surge generator of 1.2x50 µs open-circuit voltage waveform (8x20 µs short-circuit current waveform) per
IEEE C62.41 may be used. The current shall be limited by the inclusion of a series 6
W
resistor for Test 1 and a 12
W
resistor for
Test 2, placed externally to the surge generator.