1. General Remarks
These connectors are designed and produced in conformity with the
low voltage directive (73/23/EWG) respectively Gerätesicherheitsgesetz
(German law) and are especially in accordance with the standards
DIN EN 61984 / IEC 61984 (VDE0627); IEC 60664-1 (VDE 0110-1)
and IEC 60529.
The connectors may be used only within the technical ratings.
All technical data refer to mated connectors under live conditions.
The safety of the connector system depends on the correct selection of
products, proper assembly of the connector device and a precise fit of
the connectors.
2. Application Remarks
Connectors with / without breaking capacity must be used according to
specified technical ratings.
The technical data represents the initial value of mated parts under
predetermined conditions and length of time.These values could change
with different test parameters or product requirements.
The connectors of the
series are designed for the areas of
application including the construction and installation of controlling
and electrical devices.
The product has been tested for the intended purposes only. If the
connection is used other than originally intended, or in another
manner that we have not previously tested, the consumer assumes full
responsibility.
All rated data for the connectors listed in this catalogue are based on over-
voltage category III and pollution degree 3 for electronic applications if
not stated differently. Connectors were completely mated according to their
respective safety locking mechanism. Selection and testing of connectors
with / without breaking capacity to meet specific product or industrial
requirements such as rated voltage and the related clearances and creepage
distances are the responsibility of the user.
3. Assembling Remarks
Protection against electrical shock of the termination of the connectors
shall be secured by correct mounting. Connectors of the same or different
series being mounted side by side may be protected against incorrect
mating by the use of coding options. Care must be taken to ensure the
parts are correctly mated and screws are tightened with the proper torque.
4. Termination Remarks
Cable connectors are effectively secured when using the strain relief (internal
clamping ring). All cable properties or specifications must becompatible
with the connector design and materials.
Please make sure that the usability of the cable in conjunction with the clamping
ring is given.
Designated wire conductors must be terminated to the correct poles in the
connector.
Crimp contacts must be fully inserted into the plastic housing and strain relief
assured with a slight tug on the wire.
Wire should be stripped correctly according to printed specifications to insure
no electrical contact can be made between the conductors. There should be no
nicked or cut strains during the stripping action.