WM_PRJ_Q2400_PTS_002 - 002
24th January 2003
2.14.1 Operating sequences
2.14.1.1 Power ON
Once the module supplied, the application must set the ON/OFF signal to high
to start the module power ON sequence. The ON/OFF signal must be hold for
1000ms minimum. After this time, an internal mechanism keeps it on hold.
During the power ON sequence, an internal reset is automatically performed by
the module for 240ms (typical). During this phase, any external reset should be
avoided. Once the initialisation is complete (timing is SIM and network
dependent) the AT interface answers « OK » to the application
. For further
details, please check the AT commands manual (+WIND, +WAIP)
POWER SUPPLY
ON/OFF
T
on/off-hold
(1000ms min)
INTERNAL RST
T
rst
(240ms typ)
AT answers « OK »
STATE OF THE MODULE
Module OFF
I
BB+RF
< 10µA
RESET mode
I
BB+RF
=20 to 40mA
I
BB+RF
<120mA
(no loc. update)
Module ON
Module READY
SIM and Network dependent
I
BB+RF
= overall current consumption (Base Band + RF part)
Figure 10 : Power-ON sequence (no PIN code activated)
3
For this, the application has to send AT↵. If the application manages hardware flow control, the
AT command can be sent during the initialisation phase. Another solution is to use the +WIND
command to get an unsolicited status from the module.
Page :
40 / 81
confidential ©
This document is the sole and exclusive property of WAVECOM. Not to be distributed or divulged
without prior written agreement.
Ce document est la propriété exclusive de WAVECOM. Il ne peut être communiqué ou divulgué à
des tiers sans son autorisation préalable.
Go Upload

* Only PDF files are allowed for upload

* Enter up to 200 characters.