WM_PRJ_Q2400_PTS_002 - 002
24th January 2003
6 Appendix
6.1 Wavecom acceptance test
These tests are Wavecom internal qualification tests. They are performed on a
Wavecom evaluation platform (module on test board).
Test
Performance
Test
Applied standard
Acceptance criteria
Mobile Station (MS) conformance Full conformity to the recommendation regarding
specification; Part 1:
the main RF parameters.
Conformance
specification
(Release 5).
3GPP TS 51.010 v5.0.0 (2002-09)
-
Therma shocks IEC 68-2-14.
Sinusoidal vibration IEC 68-2-6.
Random vibration IEC 68-2-36.
IEC 68-2-27.
IEC 68-2-29.
Corrosion test IEC 68-2-3.
The test continues even after the Cooking Test
milestone has been reached
Full conformity to the recommendation regarding
the main parameters.
No performance degradation or
degradation is allowed after test.
No performance degradation or
degradation is allowed after test.
No performance degradation or
degradation is allowed after test.
No performance degradation or
degradation is allowed after test.
mechanical
mechanical
mechanical
mechanical
Cooking Test
Stress Test
Vibration Test
Vibration Test
Shock Test
Bump Test
Humidity Test
No visible degradation of the product, both
visual and functionnal.
The unit is tested at room temperature and must
be fully operative for the main RF parameters.
Warehouse
Test
Warehouse
Test
Dust Test1
Low temperance IEC 68-2-1.
Under normal condition (room temperature) after
the test, the unit must behave in full conformity
with the main RF parameters specification.
Under normal condition (room temperature) after
the test, the unit must behave in full conformity
with the main RF parameters specification.
No visible dust in the visible areas. No more than
50 dust particules in the cabinet of the product.
The unit, tested at room temperature must be
fully operative.
High temperature IEC 68-2-2.
MIL-STD-810D, method 510-3.
Light Test1
UV radiation and temperature EDF Visual inspection on the discoloration and other
HN60E03.
degradation effects such as cracks in the
material of the unit after the test.
IEC 68-2-32.
Only minor casing degradation is allowed, with a
maximum dimension change of 1mm. The unit
must remain fully operative and full specification
for the main RF parameters.
Fall Test1
Page :
64 / 81
confidential ©
This document is the sole and exclusive property of WAVECOM. Not to be distributed or divulged