• Inventory
  • Products
  • Technical Information
  • Circuit Diagram
  • Data Sheet
Data Sheet
Home > Data Sheet > W19B320STB9G
W19B320STB9G

W19B320STB9G

Model W19B320STB9G
Description Flash, 2MX16, 90ns, PBGA48, TFBGA-48
PDF file Total 52 pages (File size: 2M)
Chip Manufacturer WINBOND
W19B(L)320ST/B
Notes:
1. See Bus Operations Table for details.
2. All values are in hexadecimal
3. Except for the read cycle and the fourth cycle of the autoselect command sequence, all bus cycles are write cycles.
4. Data bits DQ15
DQ8 are don’t care in command sequences, except for RD and PD.
5. Unless otherwise noted, address bits A20
A11 are don’t cares.
6. No unlock or command cycles required when device is in read mode.
7. The Reset command is required to return to the read mode (or to the erase-suspend-read mode if previously in Erase
Suspend) when the device is in the autoselect mode, or if DQ5 goes high (while the device is providing status
information).
8. The fourth cycle of the autoselect command sequence is a read cycle. Data bits DQ15
DQ8 are don’t care. See the
Autoselect Command Sequence section for more information.
9. The data is 99h for factory locked and 19h for not factory locked.
10. The data is 00h for an unprotected sector/sector block and 01h for a protected sector/sector block.
11. The Unlock Bypass command is required prior to the Unlock Bypass Program command.
12. The Unlock Bypass Reset command is required to return to the read mode when the device is in the unlock bypass
mode.
13. The system may read and program in non-erasing sectors, or enter the autoselect mode, when in the Erase Suspend
mode. The Erase Suspend command is valid only during a sector erase operation.
14. The Erase Resume command is valid only during the Erase Suspend mode.
15. Command is valid when device is ready to read array data or when device is in autoselect mode.
16. See Autoselect Codes table for device ID information
7.5 Write Operation Status
STATUS
Standard
Mode
Erase
Suspend
Mode
Notes:
1. DQ5 switches to ‘1’ when an Embedded Program or Embedded Erase operation has exceeded the maximum timing
limits. Refer to the section on DQ5 for more information.
2. DQ7 and DQ2 requires a valid address when reading status information. Please refer to related sections for details.
Embedded Program Algorithm
Embedded Erase Algorithm
Erase-
Suspend-
Read
Erase Suspended Sector
Non-Erase Suspended
Sector
DQ7
(Note 2)
#DQ7
0
1
Data
#DQ7
DQ6
Toggle
Toggle
No toggle
Data
Toggle
DQ5
(Note1)
0
0
0
Data
0
DQ3
N/A
1
N/A
Data
N/A
DQ2
(Note 2)
No toggle
Toggle
Toggle
Data
N/A
RY/#BY
0
0
1
1
0
Erase-Suspend-Program