U1AFS600-2FG256YI

U1AFS600-2FG256YI

Model U1AFS600-2FG256YI
Description Field Programmable Gate Array,
PDF file Total 334 pages (File size: 18M)
Chip Manufacturer MICROSEMI
Device Architecture
Flash Memory Block Characteristics
CLK
RESET
Active Low, Asynchronous
BUSY
Figure 2-44 •
Reset Timing Diagram
Table 2-25 •
Flash Memory Block Timing
Commercial Temperature Range Conditions: T
J
= 70°C, Worst-Case VCC = 1.425 V
Parameter
t
CLK2RD
t
CLK2BUSY
t
CLK2STATUS
t
DSUNVM
t
DHNVM
t
ASUNVM
t
AHNVM
t
SUDWNVM
t
HDDWNVM
t
SURENNVM
t
HDRENNVM
t
SUWENNVM
t
HDWENNVM
t
SUPROGNVM
t
HDPROGNVM
t
SUSPAREPAGE
t
HDSPAREPAGE
t
SUAUXBLK
t
HDAUXBLK
t
SURDNEXT
t
HDRDNEXT
t
SUERASEPG
t
HDERASEPG
t
SUUNPROTECTPG
t
HDUNPROTECTPG
t
SUDISCARDPG
t
HDDISCARDPG
t
SUOVERWRPRO
t
HDOVERWRPRO
Description
Clock-to-Q in 5-cycle read mode of the Read Data
Clock-to-Q in 6-cycle read mode of the Read Data
Clock-to-Q in 5-cycle read mode of BUSY
Clock-to-Q in 6-cycle read mode of BUSY
Clock-to-Status in 5-cycle read mode
Clock-to-Status in 6-cycle read mode
Data Input Setup time for the Control Logic
Data Input Hold time for the Control Logic
Address Input Setup time for the Control Logic
Address Input Hold time for the Control Logic
Data Width Setup time for the Control Logic
Data Width Hold time for the Control Logic
Read Enable Setup time for the Control Logic
Read Enable Hold Time for the Control Logic
Write Enable Setup time for the Control Logic
Write Enable Hold Time for the Control Logic
Program Setup time for the Control Logic
Program Hold time for the Control Logic
SparePage Setup time for the Control Logic
SparePage Hold time for the Control Logic
Auxiliary Block Setup Time for the Control Logic
Auxiliary Block Hold Time for the Control Logic
ReadNext Setup Time for the Control Logic
ReadNext Hold Time for the Control Logic
Erase Page Setup Time for the Control Logic
Erase Page Hold Time for the Control Logic
Unprotect Page Setup Time for the Control Logic
Unprotect Page Hold Time for the Control Logic
Discard Page Setup Time for the Control Logic
Discard Page Hold Time for the Control Logic
Overwrite Protect Setup Time for the Control Logic
Overwrite Protect Hold Time for the Control Logic
–2
7.99
5.03
4.95
4.45
11.24
4.48
1.92
0.00
2.76
0.00
1.85
0.00
3.85
0.00
2.37
0.00
2.16
0.00
3.74
0.00
3.74
0.00
2.17
0.00
3.76
0.00
2.01
0.00
1.88
0.00
1.64
0.00
–1
9.10
5.73
5.63
5.07
12.81
5.10
2.19
0.00
3.14
0.00
2.11
0.00
4.39
0.00
2.69
0.00
2.46
0.00
4.26
0.00
4.26
0.00
2.47
0.00
4.28
0.00
2.29
0.00
2.14
0.00
1.86
0.00
Std.
10.70
6.74
6.62
5.96
15.06
6.00
2.57
0.00
3.69
0.00
2.48
0.00
5.16
0.00
3.17
0.00
2.89
0.00
5.01
0.00
5.00
0.00
2.90
0.00
5.03
0.00
2.69
0.00
2.52
0.00
2.19
0.00
Units
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns