S912XEG128J2VAL

Model S912XEG128J2VAL
Description IC,MICROCONTROLLER,16-BIT,CPU12 CPU,CMOS,QFP,112PIN,PLASTIC
PDF file Total 1327 pages (File size: 7M)
Chip Manufacturer ROCHESTER
Chapter 26 384 KByte Flash Module (S12XFTM384K2V1)
Table 26-66. Erase Verify D-Flash Section Command Error Handling
Because of an order from the United States International Trade Commission, BGA-packaged product lines and part numbers indicated here currently are not
available from Freescale for import or sale in the United States prior to September 2010: S12XE products in 208 MAPBGA packages
Register
Error Bit
Error Condition
Set if CCOBIX[2:0] != 010 at command launch
Set if a Load Data Field command sequence is currently active
Set if command not available in current mode (see
Table 26-30)
ACCERR
FSTAT
Set if an invalid global address [22:0] is supplied
Set if a misaligned word address is supplied (global address [0] != 0)
Set if the global address [22:0] points to an area of the D-Flash EEE partition
Set if the requested section breaches the end of the D-Flash block or goes into
the D-Flash EEE partition
FPVIOL
MGSTAT1
MGSTAT0
FERSTAT
EPVIOLIF
None
Set if any errors have been encountered during the read
Set if any non-correctable errors have been encountered during the read
None
26.4.2.17 Program D-Flash Command
The Program D-Flash operation programs one to four previously erased words in the D-Flash user
partition. The Program D-Flash operation will confirm that the targeted location(s) were successfully
programmed upon completion.
CAUTION
A Flash word must be in the erased state before being programmed.
Cumulative programming of bits within a Flash word is not allowed.
Table 26-67. Program D-Flash Command FCCOB Requirements
CCOBIX[2:0]
000
001
010
011
100
101
0x11
FCCOB Parameters
Global address [22:16] to
identify the D-Flash block
Global address [15:0] of word to be programmed
Word 0 program value
Word 1 program value, if desired
Word 2 program value, if desired
Word 3 program value, if desired
Upon clearing CCIF to launch the Program D-Flash command, the user-supplied words will be transferred
to the Memory Controller and be programmed. The CCOBIX index value at Program D-Flash command
launch determines how many words will be programmed in the D-Flash block. No protection checks are
made in the Program D-Flash operation on the D-Flash block, only access error checks. The CCIF flag is
set when the operation has completed.