• Inventory
  • Products
  • Technical Information
  • Circuit Diagram
  • Data Sheet
Data Sheet
Home > Data Sheet > S912XEG128J2VAL
S912XEG128J2VAL

S912XEG128J2VAL

Model S912XEG128J2VAL
Description IC,MICROCONTROLLER,16-BIT,CPU12 CPU,CMOS,QFP,112PIN,PLASTIC
PDF file Total 1327 pages (File size: 7M)
Chip Manufacturer ROCHESTER
Chapter 27 512 KByte Flash Module (S12XFTM512K3V1)
Table 27-38. Erase Verify P-Flash Section Command Error Handling
Because of an order from the United States International Trade Commission, BGA-packaged product lines and part numbers indicated here currently are not
available from Freescale for import or sale in the United States prior to September 2010: S12XE products in 208 MAPBGA packages
Register
Error Bit
Error Condition
Set if CCOBIX[2:0] != 010 at command launch
Set if a Load Data Field command sequence is currently active
Set if command not available in current mode (see
Table 27-30)
ACCERR
Set if an invalid global address [22:0] is supplied
FSTAT
Set if a misaligned phrase address is supplied (global address [2:0] != 000)
Set if the requested section crosses a 256 Kbyte boundary
FPVIOL
MGSTAT1
MGSTAT0
FERSTAT
EPVIOLIF
None
Set if any errors have been encountered during the read
Set if any non-correctable errors have been encountered during the read
None
27.4.2.4
Read Once Command
The Read Once command provides read access to a reserved 64 byte field (8 phrases) located in the
nonvolatile information register of P-Flash block 0. The Read Once field is programmed using the
Program Once command described in
Section 27.4.2.7.
Table 27-39. Read Once Command FCCOB Requirements
CCOBIX[2:0]
000
001
010
011
100
101
0x04
FCCOB Parameters
Not Required
Read Once phrase index (0x0000 - 0x0007)
Read Once word 0 value
Read Once word 1 value
Read Once word 2 value
Read Once word 3 value
Upon clearing CCIF to launch the Read Once command, a Read Once phrase is fetched and stored in the
FCCOB indexed register. The CCIF flag will set after the Read Once operation has completed. Valid
phrase index values for the Read Once command range from 0x0000 to 0x0007. During execution of the
Read Once command, any attempt to read addresses within P-Flash block 0 will return invalid data.
128
MC9S12XE-Family Reference Manual , Rev. 1.19
Freescale Semiconductor
1053