• Inventory
  • Products
  • Technical Information
  • Circuit Diagram
  • Data Sheet
Data Sheet
Home > Data Sheet > S912XEG128J2VAL
S912XEG128J2VAL

S912XEG128J2VAL

Model S912XEG128J2VAL
Description IC,MICROCONTROLLER,16-BIT,CPU12 CPU,CMOS,QFP,112PIN,PLASTIC
PDF file Total 1327 pages (File size: 7M)
Chip Manufacturer ROCHESTER
Chapter 29 1024 KByte Flash Module (S12XFTM1024K5V2)
Table 29-44. Program P-Flash Command Error Handling
Because of an order from the United States International Trade Commission, BGA-packaged product lines and part numbers indicated here currently are not
available from Freescale for import or sale in the United States prior to September 2010: S12XE products in 208 MAPBGA packages
Register
Error Bit
Error Condition
Set if CCOBIX[2:0] != 101 at command launch
Set if command not available in current mode (see
Table 29-30)
Set if an invalid global address [22:0] is supplied
ACCERR
Set if a misaligned phrase address is supplied (global address [2:0] != 000)
Set if a Load Data Field command sequence is currently active and the selected
block has previously been selected in the same command sequence
FSTAT
Set if a Load Data Field command sequence is currently active and global
address [17:0] does not match that previously supplied in the same command
sequence
FPVIOL
MGSTAT1
MGSTAT0
FERSTAT
EPVIOLIF
Set if the global address [22:0] points to a protected area
Set if any errors have been encountered during the verify operation
Set if any non-correctable errors have been encountered during the verify
operation
None
29.4.2.7
Program Once Command
The Program Once command restricts programming to a reserved 64 byte field (8 phrases) in the
nonvolatile information register located in P-Flash block 0. The Program Once reserved field can be read
using the Read Once command as described in
Section 29.4.2.4.
The Program Once command must only
be issued once since the nonvolatile information register in P-Flash block 0 cannot be erased.
Table 29-45. Program Once Command FCCOB Requirements
CCOBIX[2:0]
000
001
010
011
100
101
0x07
FCCOB Parameters
Not Required
Program Once phrase index (0x0000 - 0x0007)
Program Once word 0 value
Program Once word 1 value
Program Once word 2 value
Program Once word 3 value
Upon clearing CCIF to launch the Program Once command, the Memory Controller first verifies that the
selected phrase is erased. If erased, then the selected phrase will be programmed and then verified with
read back. The CCIF flag will remain clear, setting only after the Program Once operation has completed.
The reserved nonvolatile information register accessed by the Program Once command cannot be erased
and any attempt to program one of these phrases a second time will not be allowed. Valid phrase index
MC9S12XE-Family Reference Manual Rev. 1.19
Freescale Semiconductor